Quick reference as well as more pics and info for gable vents.
Fire rated attic vents.
The intumescent coating is designed to quickly swell up and close off when exposed to high heat.
It shows fire penetrating a frieze block vent with flames entering into what would be the attic.
The vulcan vents are the only fire resistant vents that meet both the wildland urban interface wui and the one 1 hour fire test standards for the exterior of buildings all while providing the proper amount of ventilation to attic and crawl spaces in building structures.
14 x 18 inch flat front fire stop gable vent.
Gables like dormers are vertically oriented vents best placed as high as possible.
The core of our fire and ember safe vents are manufactured out of hi grade aluminum honeycomb and coated with an intumescent fire proof coating.
The importance of ember and flame entry into vents during wildfires has resulted in the development of commercially available vents designed to resist the intrusion of embers and flame and recomendations for new or retrofit vents to protect existing openings.
Ember entry through vents can result in ignition of combustible materials in the attic and result in a building burning from the inside out.
Used in outer wall gable area.
When used in conjunction with lower soffit or eave vents rapid cooling and venting of the attic can take place.
Vulcan vents are the perfect fire stopping vent for your home.
81 sqin net free venting area.
Vulcan vents are listed by the california state fire marshal under category 8165 of the building material listing program.
Vents are vulnerable to wildfires when embers and flames enter into the enclosed attic or crawl spaces and ignite combustible materials in those areas.
This is a photograph from a test conducted in a fire research laboratory.
Shipping leadtime 4 6 business days 93 00 sale 71 95.
For flush mount over wood etc.
Approaching fire generates heat whichtriggers the vulcan vent to close.
Flame ember resistant vents naturally provide less airflow than regular unprotected vents and brandguard vent airflow ratings nfva are approximately 30 that of the same size standard 1 4 screened vent and are listed within each products description.
As seen on this old house vulcan vents are designed to be fire and ember safe.
Under eave soffit vents important airflow notes.
An ember catching screen blocks dangerous embers during ember attacks long before the fire arrives.
Vulcan 14 wide x 18 inch high fire stopping vent with flat front flange face.
These patented attic vents are accepted for use by many local fire officials for installation in wildland urban interface wui zones.