O roofing underlayment felts applied to a minimum.
Fha attic ventilation requirements.
Goal is to design an attic ventilation system that effectively compensates for the additional heat gain produced by the high levels of insulation.
Calculating attic ventilation requirements.
Change the square feet to square inches.
One frequently asked question about the fha loan process is related to fha appraisals and the minimum requirements for the roof of the home.
For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing the amount of attic ventilation to account for the additional.
Non perforated saturated felt or equal.
When there is no safe access to the attic the appraiser is to note the inaccessibility in the appraisal report.
Ensuring that mixed use properties comply with zoning.
Clarifying that fha requires an inspection.
4 roofing underlayment felts.
Ventilation shall be provided concurrently with the.
It s the appraiser s job to look over the home make sure it meets fha standards and assign it a fair market value.
Regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
At a minimum the appraiser must enter head and shoulders into the attic.
170 roof sheath temperature 140 attic temperature 115 attic temperature 4 section 1 hows and whys of attic ventilation.
All appropriate approaches must be utilized when applicable.
In short effective attic ventilation also helps cool attic insulation.
Result of item 1 300.
Calculate the square footage of the attic space.
Cost and income approach for value.
Inspection the attic must be examined whether access is by pull down stairway or scuttle.
O low sloped shingle roofs 2 in 12 to 4 in 12.
General acceptance criteria property eligibility and non residential use of property.
The attic must be entered at a minimum by head and shoulders whether access is by pull down stairway or scuttle.
Result of item 3 2.
Attic and crawl space inspection requirements.
Sloped roof of 4 in l2 shall be 15 pound asphalt.
Owens corning recommends a balanced ventilation system based on the u s.
Divide the square inches by 2.
Divide the square footage item 1 by 300.
The appraiser must enter the attic and observe the interior roof structure and attic for evidence of leaks water damage structural problems previous fire damage frt sheathing exposed and frayed wiring deficient materials deficient insulation and adequate ventilation by vent fan or window.
Result of item 2 x 144.